2 on/off control – SENA Rhio232 User Manual

Page 35

Advertising
background image

35

- NAK Response

START

FLAG

LENGTH

FUNCTION

DATA

LRC

(BCC)

END

FLAG

Byte

Size

1

2

2

3

2

2

Start

of

the

Command

Block,

0x3A

( “:” )

The length from

FUNCTION field

to DATA field

Response

“00”

0x30,0x30

NAK

Data

“NAK”

0x4E,

0x41,

0x4B

XOR

from

LENGTH

field to DATA

field

CR (0x0D)

LF (0x0A)

HOST

RHIO

Command

Send Response if it receives the correct command set

Send

NAK Response (BCC Error or Timer out or Length calculation error)

-. Users have to write code to send the command again or display NAK status if the program

receives NAK Response.

* NOTE: In the following descriptions, each port is indicated as below:

-

Input Port: I1 - I12

-

ADC Input: A1 - A4 (Level Input and Switch Input modes)

-

Output Port: O1 - O10

4.3.2 ON/OFF Control

4.3.2.1 ON/OFF Control Command

Command

Data

Remark

Byte Size

2

“01”

( 0x30, 0x31 )

ON/OFF control

10-point output masking and

ON/OFF control data

Send output points to set

ON/OFF in a batch.