Appendix b troubleshooting, B.1 power/led status troubleshooting, B.2 serial console troubleshooting – SENA Rhio232 User Manual

Page 57

Advertising
background image

57

Appendix B Troubleshooting

B.1 Power/LED Status Troubleshooting

Problem

Cause

Action

Power LED does not
light up

Power

cable

is

not

connected

Check power connection. The Rhio232’s power
specification is DC 9V~48V.

Serial

cable

is

not

connected

Check serial cable connection

Serial Rx LED does
not light up

Invalid serial cable is
used

Must use serial cable (or CAT5 Straight Cable +
DB9F Straight adaptor).

Serial cable is not

connected

Check serial cable connection

Serial Tx LED does

not light up

Invalid serial cable is

used

Must use serial cable (or CAT5 Straight Cable +

DB9F Straight adaptor).

B.2 Serial Console Troubleshooting

Problem

Cause

Action

Serial

cable

is

not

connected

Check serial cable connection

Invalid serial cable is
used

Must use serial cable (or CAT5 Straight Cable +
DB9F Straight adaptor).

The

Rhio232

is

not

communicated

Serial

Baud

rate

is

incorrect

Check serial port configuration of host or device
server: 9600 bps, 8 Data bits, No parity, 1 stop
bit, Hardware flow control