7 port enable setting – SENA Rhio232 User Manual

Page 43

Advertising
background image

43

-

Setting Flag

0x30: Set OK

0x31: Not in Setting mode (in Run mode)

0x39: Set NG

4.3.6.3 Check ADC Input Port Setting Command

Command

Data

Remark

Byte Size

2

1

“10”

( 0x31, 0x30 )

Check the ADC

setting

0x30: Fixed to a dummy

value

Check the

threshold level

value of an input

ADC port.

4.3.6.4 Response for Check ADC Input Port Setting command

-

Same as "4.3.6.2 Response for Set Port command".

-

The setting field is always OK (0x30).

-

The factory default value in Level Input mode is set to "0000".

4.3.7 Port Enable Setting

4.3.7.1 Set Port Enable command

Command

Data

Remark

Byte Size

2

34

“11”

( 0x31, 0x31 )

Set to Enable.

Port Enable/Disable setting data

Set all ports to

Enable/Disable.

-

Data

Field

Data Order

Port

Data Content

1

A1

2

A2

3

A3

ADC Port

4

A4

0x31: Level Input mode

0x32: Switch Input mode

Advertising