Serial ports, 4 data bit, 5 hardware flow control – SENA Parani-SD200L User Manual

Page 13

Advertising
background image

13

Table 3-2 The Parani-SD200L LED Indicators

Indicator

Power LED

Standby LED

Connect LED

Mode0

Green (every 0.5 sec)

┏┓

Red (every 0.5 sec)

┏┓

Off

Mode1

Green (every 0.5 sec)

┏┓

Off

Green (every 1 sec)

┏┓

Mode2

Green (every 0.5 sec)

┏┓

Off

Green (every 3 sec)

┏┰┓

Mode3

Green (every 0.5 sec)

┏┓

Off

Green (every 3 sec)

┏┰┓

Connected

Green (every 0.5 sec)

┏┓

Off

Green

┏━━━━━━━

Low Battery

Green (every 0.5 sec)

┏┓

Red (every 0.2 sec)

┏┓

charging

Green (every 0.5 sec)

┏┓

Red

┏━━━━━━━

Full charging

Green

┏━━━━━━━

Red (every 0.5 sec)

┏┓

3.3. Serial Ports

The applicable settings for serial ports are as follows.

Table 3-3 The Parani-SD200L Serial Port Settings

Serial Port Settings

Values

Baud rate

1200, 2400, 4800, 9600, 19200, 38200, 57600, 115200, 230400

Data bite

8

Parity

No parity , Even parity, Odd parity

Stop bit

1 , 2

Hardware Flow Control

Use, No Use

The values in box are the factory defaults. The flow control setting is configurable only through dip
switch.

3.4 Data Bit

Parani-SD200L supports only 8 data bit. In the case of 7 data bit and even/odd parity, use SD 8 data
bit and none parity. At this time, master and slave are SD, ESD or MSP series. But 7 data bit and none
parity is not support.

3.5 Hardware Flow Control

Parani-SD200L plugged into its host system transmits data from host to the other side Bluetooth
device. This data is saved temporarily in the internal buffer of Parani -SD200L and sent repeatedly until
the transmission is completed packet by packet. When the radio transmission condition is not good
enough to send data promptly, it can cause a transmission delay. If the host sends more data when the
buffer is full, buffer overflow will make Parani-SD200L malfunction consequently. In order to prevent
this buffer overflow, Parani-SD200L works as follows.

When using hardware flow control, Parani-SD200L disables RTS so that it stops receiving any further
data from the host when the buffer becomes full. RTS will be re-enabled again to begin receiving data
from the host when the buffer has created more room for more data.

When hardware flow control is not being used, the Parani-SD200L clears the buffer to secure room for