B.3. command description, B.3.1. atz, B.3.2. at&f – SENA Parani-SD200L User Manual

Page 30: B.3.3. at, B.3.4. at+uartconfig,baudrate,parity,stopbit

Advertising
background image

30

B.3. Command Description

B.3.1. ATZ

SD Response

OK

Purpose

Software Reset

Description

This has the same effects as Powercycling the unit.
This command disconnects any connected Bluetooth device, and stops ongoing tasks.
After rebooting, the status will be decided by the preset operation mode.
Some AT commands require the ATZ command be run so that the commands can take
effect.

Reference

AT&F, AT+BTCSD, AT+UARTCONFIG

B.3.2. AT&F

SD Response

OK

Purpose

Hardware reset

Description

This has the same effect as initialization by pressing the factory reset button.
All parameters are initialized to factory defaults.

Reference

ATZ

B.3.3. AT

SD Response

OK

Purpose

Check the connection status with host equipment

Description

Check if the connection to host equipment is operating normally. The serial parameters of
Parani-SD200L must be same as those of host equipment. If not, the SD will not respond
or ‘ERROR’message will appear or an abnormal sequence of strings will appear.

Reference

AT+UARTCONFIG, ATZ, AT&F

B.3.4. AT+UARTCONFIG,Baudrate,Parity,Stopbit

SD Response

OK

Purpose

Set Serial parameters

Parameters

Baudrate=1200/2400/9600/14400/19200/38400/57600/115200/230400 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)

Description

The Serial parameters can be set or changed only if SW config mode is selected in dip
switch. The factory default is 9600, N, 1.
To take effect the ATZ command must be used or Powercycle the unit.

Reference

AT, ATZ, AT&F, ATS

Example

AT+UARTCONFIG,9600,N,1

Advertising