B.3.28. at+btrssi,n, B.3.29. at&v, B.3.30. atsnn – SENA Parani-SD200L User Manual

Page 37: B.3.31. atsnn=mm

Advertising
background image

37

Parameters

n=0: Inactivate (Default)
n=1: Activate

Description

During no data transmission, Parani-SD200L can be in low power mode to save the power.
It takes a few seconds to wake the Parani-SD200L out of low power mode.

B.3.28. AT+BTRSSI,n

SD Response

OK
0,255,0,0(repeatedly)

Purpose

Test signal strength

Parameters

n=0: Stop signal strength test
n=1: Start signal strength test

Description

When Bluetooth connection is established, you can use this command in Standby status.
The signal strength will be displayed repeatedly in order of Status, LinkQuality, Status,
RSSI. If the LinkQuality is close to 255 and RSSI is close to 0, the signal strength is in good
standing.

Example

+++
AT+BTRSSI,1

OK
0,255,0,0

B.3.29. AT&V

SD Response

S0:m0;S1:m1; …Sn:mn
OK

Purpose

Display all the S-registers

Description

All parameters are stored at S-register in flash memory. These values are sustained until a
hardware reset.

Reference

ATS

B.3.30. ATSnn?

SD Response

value
OK

Purpose

Display a given S-register

Parameters

nn= Address of S-register

Description

A specific S-register will be displayed.

Reference

AT&V

B.3.31. ATSnn=mm

SD Response

OK

Purpose

Change S-register value

Advertising