Isbus configuration – GE Industrial Solutions Control System Toolbox For an AV-300i Version 2 Drive User Manual

Page 61

Advertising
background image

GEH-6412 Toolbox for AV-300i Version 2 Drive

Chapter 4 Configuring an AV-300i Version 2 Drive

••••

4-31

Located below the Title bar is the toolbar, as described below:

Click…

To…

Hold the Finder Window open. If this button is displayed in the window, the Window
closes when the area outside the Finder Window is clicked. Click on the pushpin to
keep the Finder on top of the Device Window, even when you click outside the
Finder Window.

Close the Finder Window. This button is displayed when the pushpin above is
clicked on. The Finder Window remains opens when the pushpin is in this position
(even when working in another window).

Goto an item in the Outline View. Highlight an item in the Output View, then click
this button to find it in the Outline View. Double-click on the item to edit it.

Hide the tabs and make the Finder window display only the Output View.

ISBus Configuration

The ISBus provides a
high-speed connection
between drives and
controllers for both
synchronous and
asynchronous data.

This section describes how to insert the AV300i ISBus Interface (option card
6KCV301 ISBus) for AV-300i Version 2 drives and assign the data, which is to be
exchanged. The ISBus is commonly used to coordinate a set of drives with a
controller. Physically, it is a ring topology.

Communication is through a master/slave arrangement, where only the master can
communicate with a slave. Each bus can have only one master node. Depending on
the hardware platform, up to four ISBuses can be connected to a controller, with
letters A to D distinguishing each bus. The ISBus is also used to send asynchronous
data from the toolbox to the drive. This feature supports the upload and download of
parameters and trending over an Ethernet connection through the controller to drives
on the ISBus. The following diagram shows a typical connection.

Ethernet to

Innovation Series

controller

using the toolbox

Innovation

Series

Controller

AV-300i

with

ISBus
option

ISBus A

ISBus B

ISB1

RxTx

Tx

Note This ISBus setup,
using bypass modules,
allow drives to be shut off
and maintain the ISBus
ring and functions.

ISBus bypass

246B9949BJG01

P2

P2

P2

P2

P2

P3

P3

P3

P3

P3

P1

P1

P1

P1

P1

AV-300i

with

ISBus
option

AV-300i

with

ISBus
option

AV-300i

with

ISBus
option

AV-300i

with

ISBus
option

ISBus bypass

246B9949BJG01

ISBus bypass

246B9949BJG01

ISBus bypass

246B9949BJG01

ISBus bypass

246B9949BJG01

Ethernet

RxTx

Tx

RxTx

Tx

RxTx

Tx

RxTx

Tx

ISBus

splitter

module

(IS200ISBDG2)

*

Tx

RxTx

P1

P3

P2

Advertising