The pipe cover protects the plumbing pipes to

the water heater from unexpected adjustments.

This pipe cover is fixed to the bottom of the water

heater, which hides the plumbing and improves

the visual aspects of the whole installation for the

water heater.

5. 3" ULC S636 PVC Concentric Termination: TH-CVPVC33

Used when terminating direct-vent (sealed-combustion)

systems, with direct-vent models that require a 76 mm (3

in.) intake and a 76 mm (3 in.) exhaust. This concentric

termination provides the convenience of only having to

make one penetration through a sidewall instead of two

separate penetrations for the intake and exhaust piping.

The termination includes a bird screen, restricting small

animals, pests, and foreign objects from entering into the

vent system.

NOTE:

Concentric (single penetration) terminations are

only permitted for sidewall (horizontal) terminations.

Roof (vertical) terminations must use two separate

penetrations.

Installation

Installation Manual

The temperature remote controller has two

functions. It allows the output temperature from

the water heater to be adjusted within the range

of 38 °C to 85 °C, and it also works as a diagnostic

tool that will give a concise error code whenever

there is a problem with the unit. The temperature

options are 38 °C (100 °F), 40 °C (105 °F), 43 °C

(110 °F), 45 °C (115 °F), 50 °C (120 °F), 52 °C (125

°F), 55 °C (130 °F), 57 °C (135 °F), 60 °C (140 °F), 63

°C (145 °F), 65 °C (150 °F), 68 °C (155 °F), 70 °C (160

°F), 75 °C (165 °F), 80 °C (175 °F) and 85 °C (185 °F).

See the troubleshooting section for information

on possible error codes.

1. Temperature remote controller:

TM-RE40

2. Backflow Preventer: TK-BF01

The backflow preventer prevents the backflow

of air through the exhaust vent. This helps

prevent harmful exhaust gases from entering

the home, as well as helping to prevent the

unit from freezing in areas where cold air can

be blown or drawn into the exhaust system.

Install this vent damper in accordance with

the installation instructions and any applicable

codes.

3. Pipe covers: TH-PC03

4. Neutralizer kit: TH-NT01

The neutralizer assembly

neutralizes the condensate

(acidic water) that forms in the

secondary heat exchanger of

the water heater.

It connects to the condensate

drain port of the water heater

by using connectors included

with the neutralizer kit. Refer

to p. 24 for the details.