Specifications – John Wood Takagi - 240H-340H-540H User Manual

Page 4

Advertising
background image

4

Page

SPECIFICATIONS

*275790 pa (40 psi) or above is recommended for maximum flow.

** The Manifold Pressure is the factory setting and generally should not need adjustment.

NOTE:

• Check the rating plate to ensure this product matches your specifications.

• In accordance with CSA 4.3, CO emission does not exceed 400 ppm for normal input.

The manufacturer reserves the right to discontinue, or change at any time, specifications or designs

without notice and without incurring obligation.

Specifications

Installation Manual

Model

T-H3J-DV / 240H

T-H3S-DV / 340H

T-H3-DV / 540H

Natural Gas Input

(Operating Range)

BTU/h

Min.: 15,000

Max.: 160,000

Min.: 15,000

Max.: 180,000

Min.: 15,000

Max.: 199,000

Propane Input

(Operating Range)

BTU/h

Min.: 13,000

Max.: 160,000

Min.: 13,000

Max.: 180,000

Min.: 13,000

Max.: 199,000

Gas Connection

3/4" NPT

Water Connections

3/4" NPT

Water Pressure*

MPa

(psi)

0.1 - 1 (15 - 150)

Natural gas

Inlet Pressure

kPa

(" W.C.)

Min. 1.24 (5.0)

Max. 2.61 (10.5)

Propane

Inlet Pressure

MPa

(" W.C.)

Min. 1.99 (8.0)

Max. 3.48 (14.0)

Manifold

Pressure**

Natural

Gas

Pa

(" W.C.)

373

(1.50)

610

(2.45)

734

(2.95)

Propane

Pa

(" W.C.)

523

(2.10)

672

(2.7)

821

(3.3)

Weight

kg (lbs.)

26.3 (58)

26.3 (58)

26.8 (59)

Dimensions

mm

H 570 x W 450 x D 272

H 22.4 x W 17.7 x D 10.7

inch

Ignition

Electric Ignition

Electric

Supply

VAC / Hz

120 / 60

Consump

tion

Operation

W / A

72.7 / 0.61

78.2 / 0.65

89.0 / 0.74

Standby

W / A

3.1 / 0.03

3.1 / 0.03

4.2 / 0.04

Freeze-

Protection

W / A

174 / 1.5

174 / 1.5

175 / 1.5

Advertising