• The maximum length of exhaust vent piping must not exceed 21.3 m (70 ft.) for 76 mm (3”)

venting, which depends on the elevation where the water heater is installed. 30.5 m (100 ft.)

for 102 mm (4”) venting (deducting 1.5 m (5 ft.) for each elbow used in the venting system). Do

not use more than 5 elbows. See the table below.

• When the horizontal vent run exceeds 1.5 m (5 ft.), support the vent run at 0.9 m (3 ft.) intervals

with overhead hangers.

-Plastic Venting Illustrations-

For details of the optional items, refer to the Installation manual for each Optional item.

Installation

Installation Manual

No. of Elbows

Max. Vertical or Horizontal (Total) Vent Length

76 mm (3") venting

102 mm (4") venting

Elevations up

to 3,000 ft

Elevations up

to 6,000 ft

Elevations up

to 10,100 ft

Elevations up

to 10,100 ft

0

21.3 m (70 ft.)

12.2 m (40 ft.)

7.6 m (25 ft.)

30.5 m (100 ft.)

1

19.8 m (65 ft.)

10.7 m (35 ft.)

6.1 m (20 ft.)

29.0 m (95 ft.)

2

18.3 m (60 ft.)

19.1 m (30 ft.)

4.6 m (15 ft.)

27.4 m (90 ft.)

5

13.7 m (45 ft.)

N/A

N/A

22.9 m (75 ft.)

Diameter

Max. No. of Elbows Max. Vertical and Horizontal (Total) Vent Length

76 mm (3 in.)

5

21.3 m (70 ft.)

102 mm (4 in.)

5

30.5 m (100 ft.)

*For each elbow added, deduct 1.5 m (5 ft.) from max. vent length.

Excludes vent terminators, termination elbows, or rain caps

For details on the vent connection to these models, refer to p. 16.

Horizontal Installation Diagram

Vertical Installation Diagram

Roof

Flashing

Roof

Fire stop

Wall

Connect between exhaust vent collar and plastic piping.

See the next page for instructions.