-Natural Gas Supply Piping-

Maximum delivery Capacity of Cubic Feet of Gas per Hour of IPS Pipe carrying Natural Gas with 0.60 Specific Gravity

Based on Pressure Drop of 0.5" W.C.

Based on Energy Content of 1,000 BTU/Cubic ft.: The water heater requires 160 Cubic ft./hr for the T-H3J-DV /

240H, 180 Cubic ft./hr for the T-H3S-DV / 340H, and 199 Cubic ft./hr for the T-H3-DV / 540H.

-Propane (LP) Supply Piping-

Maximum Capacity of Propane (LP) Based on 11" W.C. supply pressure at a 0.5" W.C. pressure drop

Pipe Size

Length

Diameter 10'

20'

30'

40'

50'

60'

70'

80'

90'

100' 125' 150' 200'

3/4"

363

249

200

171

152

138

127

118

111

104

93

84

72

1"

684

470

377

323

286

259

239

222

208

197

174

158

135

1 1/4"

1,404 965

775

663

588

532

490

456

428

404

358

324

278

1 1/2"

2,103 1,445 1,161 993

880

798

734

683

641

605

536

486

416

2"

4,050 2,784 2,235 1,913 1,696 1,536 1,413 1,315 1,234 1,165 1,033 936

801

Unit: Cubic Feet per Hour

Based on Energy Content of 1,000 BTU/Cubic ft:

Divide each appliance's BTU requirement by 1,000 BTU/h to get the appliances Cubic Ft. requirement.

Take into account the distance the appliance is from the gas meter, look in the above gas chart to properly size the line.

For sections of the gas line supplying gas to more than one appliance (Ex: Point A to Point B), add up the cubic ft.

requirements of the appliances that are being supplied by that section, and size to the farthest appliance.

For Example: The section from A to B supplies gas to the furnace, range and dryer. Adding up the BTU requirements and

dividing by 1,000 yields a cubic ft. requirement of 220 cubic ft. of gas. The farthest appliance is the range, which is 50 ft.

away from the meter. Looking at the above chart, and under the column of 50 ft., Section A to B needs to be 1" in order to

supply 220 cubic ft.

Installation

Installation Manual

Water

Heater

199,000 BTU/h

Dryer

35,000 BTU/h

Gas Meter

Furnace

120,000 BTU/h

Range

65,000 BTU/h

A

B

C

10' Length

1/2" Pipe Size

15' Length

1/2" Pipe Size

15' Length

1" Pipe Size

10' Length

3/4" Pipe Size

10' Length

1" Pipe Size

5' Length

1-1/4" Pipe Size

10' Length

3/4" Pipe Size

5' Length

1-1/4" Pipe Size

Gas Sizing Example

(Natural Gas)

Unit: kBTU per Hour

Pipe Size

Length

Diameter 10'

20'

30'

40'

50'

60'

70'

80'

90'

100' 125' 150' 200'

3/4"

567

393

315

267

237

217

196

185

173

162

146

132

112

1"

1,071 732

590

504

448

409

378

346

322

307

275

252

213

1 1/4"

2,205 1,496 1,212 1,039 913

834

771

724

677

630

567

511

440

1 1/2"

3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023 976

866

787

675

2"

6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260