Maintenance and service, Unit draining and filter cleaning, Normal operation owner's guide – John Wood Takagi - 240H-340H-540H User Manual

Page 41

Advertising
background image

41

Page

MAINTENANCE AND SERVICE

• Clean the cold-water inlet filter. (Refer to diagram below.)

• Be sure that all openings for combustion and ventilation air are not blocked.

• The venting system should be checked annually for any leaks, corrosion, blockages or damage.

• The burner should be checked annually for dust, lint, grease or dirt.

• Keep the area around the water heater clear. Remove any combustible materials, gasoline or any

flammable vapors and liquids.

• In accordance with all local codes and common safety practices, water discharged from the pressure

relief valve can cause severe burns instantly from scalding. DO NOT touch the pressure relief valve.

• If the relief valve discharges periodically, it may be due to thermal expansion in a closed water supply

system. Contact the water supplier or local plumbing inspector on how to correct this situation.

• Visual check of burner flames (see below) through the burner window in the burner assembly located

at the middle of the water heater.

The manufacturer recommends having the unit checked once a year or as necessary by a licensed

technician. If repairs are needed, any repairs should be done by a licensed technician.

UNIT DRAINING and FILTER CLEANING

Normal Operation

Owner's Guide

Turn off the electrical power supply and close the manual gas shutoff valve

and the manual water control valve before servicing.

WARNING

1. Close the manual gas shutoff valve.

2. Turn off power to the unit and wait a couple of seconds.

Turn on again.

3. Wait 30 seconds, and then turn off power to the unit,

yet again.

4. Close the water shutoff valve.

5. Open all hot water taps in the house. When the

residual water flow has ceased, close all hot water taps.

6. Have a bucket or pan to catch the water from the unit’s

drain plugs. Unscrew the two drain plugs (Large and

small) to drain all the water out of the unit.

7. Wait a few minutes to ensure all water has completely

drained from the unit.

8. Clean the filter: Check the water filter located within

the cold inlet. With a tiny brush, clean the water

filter of any debris which may have accumulated and

reinsert the filter back into the cold water inlet.

9. Securely screw the drain plugs back into place.

Hand- tighten only.

Satisfactory

Blue flame

Unsatisfactory

Flame

blowing up

Unsatisfactory

Red or Yellow

flame

Water valve

Gas

valve

Drain plug

(Small)

Drain plug

with Filter (Large)

Advertising