Easy-link system – John Wood Takagi - 240H-340H-540H User Manual

Page 26

Advertising
background image

26

Page

EASY-LINK SYSTEM

(Available on the T-H3-DV / 540H Indoor only)

The T-H3-DV / 540H water heaters can be connected with allowable heaters (see the table below)

with communication cables to work as a multiple-unit manifold system.

• The Easy-Link system allows up to 4 units to manifold together.

• A communication cable (gray color) comes with each T-H3-DV / 540H model.

You can manifold from 2 to 4 units without the need for a multi-unit controller. A 4-unit system

has full automatic modulation between 13,000 BTU/h (Propane) or 15,000 BTU/h (Natural gas)

to 796,000 BTU/h.

-Easy-Link Connection Procedures-

1. Verify the set temperatures of all units within the system. Every single water heater must be set to the

same set temperature.

Installation

Installation Manual

-General-

Easy-Link connection with allowable heaters

T-H2-DV / 520H
T-H3-DV / 540H

When the T-H3-DV / 540H is connected to previous models as part of an Easy-

link system, Contact the manufacturer.

WARNING

Hot Out

Gas In

Cold In

• The Easy-Link system is limited up to 4 units. If you connect more than 4 units,

only the first 4 units will work as a part of the Easy-Link system. The other

additional units will not work.

Only listed models on the table above can be combined together as an Easy-

Link System. Different models cannot be combined together to form an

Easy-Link System.

CAUTION