Programmer’s Guide, cont’d

CrossPoint 300 Matrix Switchers • Programmer’s Guide

4-6

Command/Response Table for SIS Commands

Symbol Definitions:

= Carriage return/line feed

= Carriage return (no line feed)

= Space

Esc

= Escape key

Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit

numbers. All input and output numbers are reported as 2-digit numbers in the response.

X1

= Input number

01 – 08

(CrossPoint 300 84/88/816);

01 – 12

(CrossPoint 300 124/128);

01 – 16

(CrossPoint 300 168/1616)

X2

= Input number (for tie)

0 – maximum number of inputs (0 = disconnected)

X3

= Output number

01 – 04

(CrossPoint 300 84/124);

01 – 08

(CrossPoint 300 88/128/168);

01 – 12

(CrossPoint 300 1212);

01 – 16

(CrossPoint 300 816/1616)

X4

= Mute, Lock mode, power supply

(0 = off/mode 0/not OK, 1 = on/mode 1/OK, 2 = mode 2)

X5

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X6

= Audio gain

0 – 24 (1 dB/step) (default = 0 dB)

X7

= Audio attenuation

1 – 18 (1 dB/step)

X8

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
(default = 64 [0 dB])

X9

= Global preset #

0 – 32 (0 = current configuration)

X10

= Video/audio mute

0 = no mutes

2 = audio mute

1 = video mute

3 = video and audio mute

X11

= Firmware version number to the

second decimal place (x.xx)

X12

= Verbose firmware version-description-upload date/time.

See the Query software version (verbose) command on page 4-12.

X13

= Name

12 characters maximum for global preset names.
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.

The following characters are invalid in the name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X14

= Baud rate

9600, 19200, 38400, 115200

X15

= Parity

O

dd, even, none, mark, space (only the first letter is

required)

X16

= Data bits

7, 8

X17

= Stop bits

1, 2

X18

= Port type

0 = RS-232, 1 = RS-422

X19

= Voltage

Positive or negative voltage magnitude

X20

= Temperature

Degrees Fahrenheit

Advertising