A rapid guide to interpreting a spectrum

3. FORMULAE FOR CALCULATING TYPICAL BEARING DEFECT

FREQUENCIES

SYMBOLS:

FTF = housing frequency
BPFO = defect on outer track
BPFI = defect on inner track
BSP = defect on roller/ball

The frequencies of bearings can be calculated if we know:
S

= number of shaft rpm

PD

= primitive diameter

BD

= ball/roller diameter

N

= number of balls/rollers

Θ

= angle of contact

The most common case:
a - fixed external ring (rotating internal ring)

Θ

cos

PD

BD

S

=

FTF

1

2

Θ

cos

PD

BD

N

S

=

BPFO

1

2

Θ

cos

PD

BD

+

N

S

=

BPFI

1

2



⎟⎟

⎜⎜

Θ

2

1

2

cos

PD

BD

BD

PD

S

=

BSP

b - rotating external ring (fixed internal ring)

Θ

+

cos

PD

BD

S

=

FTF

1

2

Θ

cos

PD

BD

N

S

=

BPFO

1

2

Θ

cos

PD

BD

+

N

S

=

BPFI

1

2



⎟⎟

⎜⎜

Θ

2

1

2

cos

PD

BD

BD

PD

S

=

BSP

Approximate calculation formulae

(± 20%)

FTF = 0.4 x S (a) or 0.6 x S (b)
BPFO = 0.4 x N x S (a) or (b)
BPFI = 0.6 x N x S (a) or (b)
BSP = 0.23 x N x S (N < 10) (a) or (b)

= 0.18 x N x S (N ≥ 10) (a) or (b)