Technicaldata

Type 8006, 8702

8006 35.0 Nm3/h

Made in France

00182381

W49MM

24V DC 13W DP

CH4

S/N 1004

FKM

Type of the

device

Nominal flow rate

(Q

nom

) and unit

Operating medium

Material of the seal
Supply voltage

Max. power consumed

Output signal

Construction

code

Item no. of the

device

Serial

number

Fig. 3: Details of a name plate

Calibration data

00202378

Medium 1
P1: 0.700 barg

Mounting: Horizontal mounting
QC passed: 25.11.2011

Calibration date

Calibration

pressure

Mounting

position

Item no. of the

device

Calibration fluid

Fig. 4: Details of a calibration plate

6.2.

conditions of use

Warning

risk of injury from malfunction due to effects of the weather!
The MFM / MFC is not designed for unrestricted use outdoors.
• Protect the device from direct sunlight.
• Observe the ambient temperature range of the device.
• Protect the device from humidity.

setting

value

Ambient temperature

Types 8702 / 8712: -10 °C to +50 °C
Types 8006 / 8626: -10 °C to +45 °C
For UL devices: 0 °C to 40 °C

Medium temperature

for oxygen: -10 °C to +60 °C

for other fluids: -10 °C to +70 °C

Air humidity

< 95%, without condensation

Relative humidity for UL
devices

80% up to a temperature of 31°C,

with a linear decrease to a relative

humidity of 50% at 40°C

Protection class
according to EN 60529

Only if devices are cabled and the

connectors are plugged in and

tightened: IP65

Absolute height above
sea level for UL devices

2000 m max.

Operating environment

Indoors, with pollution degree 2