Pressure loss specifications, English – Burkert Type 8712 User Manual

Page 21

Advertising
background image

21

Technicaldata

Type 8626, 8712

6.6.3. pressure loss specifications

Q [l

N

/min]

∆p [mbar]

0

20

40

60

80

100

120

140

160

180

200

0 100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1/4''

3/8''

1/2''

3/4''

Fig. 18: Pressure loss diagram (ref. air, with 250 µm inlet filter),

type 8006

The characteristic diagram shows the air pressure loss in the device
for 3 different bases (up to 100 Nl/min, from 100 to 500 Nl/min,
from 500 to 1500 Nl/min) and 4 different connections (1/4'', 1/2'',
3/4'' and 3/8'').
For determining the pressure loss with another gas first calculate the
equivalent air flow-rate of the other gas.

0

10

20

30

40

50

60

70

80

90

100

110

120

130

0

5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

Q [l

N

/min]

∆p [mbar]

flanges

1/4''

Fig. 19: Pressure loss diagram (ref. air, with 250 µm inlet filter),

type 8702

The characteristic diagram shows the air pressure loss in the
device for versions with flange connections and versions with 1/4''
connections.
For determining the pressure loss with another gas first calculate
the equivalent air flow-rate of the other gas and respect the fluidics
needed with the other gas.

English

Advertising
This manual is related to the following products: