Maintenance,Troubleshooting

Type 8626, 8712

procedure:

To gain access to the stainless steel mesh filter disc, detach the
input flange plate [2] (see „Fig. 21“).

Take out the stainless steel mesh filter disc.

Clean the stainless steel mesh filter disc [5] using distilled water
(not tap water), acetone, isopropanol or compressed air.

Dry the parts after cleaning.

Re-insert parts in the correct sequence and position
(see „Fig. 21“). The fine mesh of the filter disc [5] must face
the input flange plate [2].

9.2.2. cleaning and recalibration at the

factory

If the sensor is excessively soiled or damaged by the operating gas,
the device may deviate significantly in terms of the mass flow-rate
measurement. Cleaning or replacement followed by recalibration at
the factory will then be required.

note

• Recalibration must be carried out at the factory as it requires

the use of very precise references and a specific digital
communication system.