Description of the name plate, Technical data, Conditions of use – Burkert Type 8072 User Manual

Page 10: Compliance to standards and directives

Advertising
background image

8

Technicaldata

5.4.

Description of the name plate

FLOW : SE32

HALL

SUPPLY:12-36V= 90mA
REL:230V 3A
PV:12-36V / 4-20mA
0.3-10m/s
S-N:1110

00560547

W45LP

Made in France

2

3

4

6

8

10

7

5

1

9

11

1.

Measured process value and type of the electronic module

2.

Type of sensor

3.

Power supply; Max. current consumption

4.

Data of the on/off output

5.

Data of the current output

6.

Conformity logo

7.

Electrical protection class: double insulation

8.

Manufacturing code

9.

Measurement range of the flow rate

10.

Order code

11.

Serial number

Fig. 1:

Name plate (example)

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature

• 8032
• 8072
• UL device

(in operation)

• -10°C...60°C
• 0°C...60°C
• 0°C...40°C

Air humidity

< 80%, non condensated

Height above sea level 2000 m max. (UL device)
Degree of pollution

Degee 2 acc. to EN 61010-1 (UL device)

Installation class

Class I acc. to UL 61010-1 (UL device)

Protection rating

IP65 acc. to EN 60529, with connectors
plugged-in and tightened or sealed

6.2.

compliance to standards and
directives

The device conforms to the EC directives through the following
standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• LVD: EN 61010-1
• Environnemental testing: Vibration: EN 60068-2-6, Shock:

EN 60068-2-27.

• Pressure: The S030 fitting complies with article 3 of §3 from

97/23/CE directive.

English

Technical data

Advertising