Burkert Type 8072 User Manual

Page 13

Advertising
background image

11

Technicaldata

Measurement range

• 8032


• 8072

• 0.3 m/s to 10 m/s,

0.3 m/s corrresponds to a flow
rate of 0.5 l/min in a DN06
fitting

• 2 to 1200 l/min, with a vis-

cosity > 5 cps;
3 to 616 l/min, with a viscosity
< 5 cps;

Accuracy

• 8032 (see Fig. 7)





• 8072

• ±1 % of the full scale

1)

, with

on site calibration or when
using the teach-in feature
or
± (1 % of the full scale

1)

+ 3%

of the measured value), when
using the standard K factor

• ±1% of the measured value

Repeatability

• 8032
• 8072

• ±0.4% of the measured value
• ±0.03% of the measured

value

Linearity (8032 only)

±0.5 % of the full scale

1)

Measuring element

paddle-wheel of the S030 fitting
or oval gears of the S070 fitting

1)

Full scale = 10 m/s

Type of fluid

depends on the fitting used
(refer to the operating instruc-
tions of the fitting used)

Fluid viscosity

depends on the fitting used
(refer to the operating instruc-
tions of the fitting used)

Rate of solid particles (8032
only)

max. 1%

Fluid temperature

• with fitting S030 in PVC
• with fitting S030 in PP
• with fitting S030 in stainless

steel, PVDF, or brass

• with S070 fitting, housing in

aluminium

• with S070 fitting, housing in

stainless steel

• 0 to 50 °C (see Fig. 8)
• 0 to 80 °C (see Fig. 8)
• -15 to 100 °C (see Fig. 8)

• max. 80 °C

• max. 100 °C

Fluid pressure

• 8032 with S030 fitting in

metal

• 8032 with S030 fitting in

plastic

• 8072 with fitting S070 with

flanges

• 8072 with any fitting S070

except S070 with flanges

• PN16 max. (see Fig. 8)

• PN10 max. (see Fig. 8)

• PN10 max.

• PN55 max.

English

Technical data

Advertising