General technical data, Mechanical data – Burkert Type 8072 User Manual

Page 11

Advertising
background image

9

Technicaldata

Acc. to the 97/23/CE pressure directive, the fitting S030 can only
be used in the following cases (depending on max. pressure, pipe
diameter and fluid):

type of fluid

conditions

Fluid group 1, par. 1.3.a

only DN ≤ 25

Fluid group 2 par. 1.3.a

DN ≤ 32
or DN > 32 and PNxDN ≤ 1000

Fluid group 1 par. 1.3.b

PNxDN ≤ 2000

Fluid group 2 par. 1.3.b

DN ≤ 200

The UL device, with order code 553431, for the United States of
America and Canada complies with the following standards:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1.

6.3.

General technical data

6.3.1. mechanical data

parts not exposed to the
fluid

material

Housing, cover

Fibre glass reinforced polycarbonate

Fixed connectors

PA

Front panel

Polyester

parts not exposed to the
fluid

material

Screws

Stainless steel

O-ring seals

FKM as standard (EDPM optional)

Dn

h with s070 fitting

H

15

85

25

100

40

117

50

135

80

175

100

176

Fig. 2:

Dimension H [mm] of the 8072 depending on the S070
fitting diameter