Available versions of the se32 electronic module – Burkert Type 8072 User Manual

Page 9

Advertising
background image

7

Description

frequency proportional to the flow rate (f = KxQ, f is the frequency in Hz, K the proportionality factor, called K factor, in pulse/litre, which is
specific to each S030 fitting, and Q is the flow rate in l/s).

• The device 8072 detects the rotation of the oval gears of the S070 fitting. The oval gears generate a measuring signal with a frequency

proportional to the flow rate. The proportionality factor, called K factor, is specific to each S070 fitting.

5.3.

Available versions of the se32 electronic module

The order codes of the S030 or S070 fittings can be taken from the related data sheet: refer to the data sheets to select the fitting suited to
your application.

se32 version

supply

voltage

output

electrical connection

ul

order code

Threshold

detector

12-36 V DC Transistor, NPN

EN 175301-803 male fixed connector

no

436474

Threshold

detector

12-36 V DC Transistor, PNP

EN 175301-803 male fixed connector

no

434871

Threshold

detector

12-36 V DC Transistor, NPN

and PNP

Male 5-pin M12 fixed connector

no

436473

yes

553431

Threshold

detector

12-36 V DC Relay

Male 5-pin M12 and male EN 175301-803 fixed connectors

no

436475

Flowmeter

12-36 V DC 4-20 mA + Relay

Male 8-pin M12 and male EN 175301-803 fixed connectors

no

560547

Flowmeter

12-36 V DC 4-20 mA + Relay

Male 5-pin M12 and male EN 175301-803 fixed connectors

no

560402

Flowmeter

12-36 V DC 4-20 mA

Male 5-pin M12 fixed connector

no

560403

English

Description

Advertising