Wiring of the version with a single relay output – Burkert Type 8072 User Manual

Page 23

Advertising
background image

21

Installationandwiring

7.3.4. Wiring of the version with a single

relay output

Warning

shock hazard due to the voltage at the relay terminals, which
is higher than 48v.
• Before powering the device, always check that the connectors

are correctly plugged-in and tightened.

the device is not tight when the en 175301-803 fixed
connector is not wired:

Unscrew the nut [1] (see Fig. 10) on the 2508 female
connector supplied with the device.

Insert the plug with order code 444509, supplied with
the device, into the cable gland.

Screw the nut back.

Plug the sealed 2508 connector onto the
EN 175301-803 fixed connector.

1

2

3

1

2

3

1: Common

2: Relay, normally closed (NC)

3: Relay, normally open (NO)

4: Not connected

Fig. 19: Pin assignment on the EN 175301-803 fixed connector

1

2

4

3

5

1: V+ (12-36 V DC)
2: not connected
3: 0 V DC
4: not connected
5: Functional earth

The position of the 5-pin M12 fixed connector is adjustable:

Unscrew the locknut.

Turn the fixed connector to the desired position, by 360° max. to
prevent the cables from twisting inside the housing.

Tighten the locknut using a spanner, while keeping the fixed
connector in the desired position.

Fig. 20: Pin assignment of the 5-pin M12 fixed connector

pin of the m12 female cable
available as accessory
equipment (order code 438680)

colour of the wire (signal)

1

brown (V+)

2

not connected

3

blue (0 V DC)

4

not connected

5

grey (functional earth)

(1) Use a voltage limiter depending on the load selected, e.g. for the solenoid
valve, an EN 175301-803 connector with integrated varistor.
(*) Functional earth

English

installation and wiring