Installation and wiring, Safety information – Burkert Type 8072 User Manual

Page 16

Advertising
background image

14

Installationandwiring

version

type of connector

Detector with
NPN/PNP tran-
sistor output

Female 5-pin M12 connector (not supplied)

Detector with
relay output

EN175301-803 (type 2508 supplied) and 5-pin
M12 (not supplied) female connectors

Flowmeter with
relay output

EN 175301-803 (type 2508 supplied) and 8-pin
M12 (not supplied) or 5-pin M12 (not supplied)
female connectors

Flowmeter
without relay
output

Female 5-pin M12 connector (not supplied)

type of connector

cable type

M12 with order code
917116

• shielded
• 3 to 6.5 mm in diameter
• with wires with a max. cross section

of 0,75 mm

2

2508 with order code
438811

• shielded
• 6 to 7 mm in diameter
• with wires with a cross section of

between 0.14 and 0.5 mm

2

7.

insTAllATion AnD WirinG

7.1.

safety information

danger

risk of injury due to high pressure in the installation
• Stop the circulation of fluid, cut off the pressure and drain the

pipe before loosening the process connections.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening

the process connections.

risk of injury due to the nature of the fluid.
• Respect the regulations on accident prevention and safety relat-

ing to the use of aggressive fluids.

risk of injury due to electrical voltage.
• Shut down the electrical power source of all the conductors and

isolate it before carrying out work on the system.

• Do not unscrew the cover of a powered device.
• Observe all applicable accident protection and safety guidelines

for electrical equipment.

English

installation and wiring

Advertising