Installation of the 8025 on the s020 fitting – Burkert Type 8025 User Manual

Page 24

Advertising
background image

24

Installation

Type 8025 / 8035

7.2.2. installation of the 8025 on the s020 fitting

2

1

3

4
5

6

Install the S020 fitting onto the pipe obeying the instructions in chap. “7.2.1”.

Check that there is a seal on the fitting and that it is not damaged. Replace the seal if
necessary.

Insert the nut 3 on the fitting 5.

Insert the snap ring 2 into the groove 4.

Check that the seal 6 is correctly inserted on the flow sensor.

Insert the device 1 into the fitting.

If the mounting is correctly done the device cannot be turned around anymore.

Hand lock the assembly with nut 3.

Fig. 11: Installation of the 8025 on the S020 fitting

7.2.3. installation of the se35 electronic module onto the s030 sensor-fitting

1

2

3

Respect the installation instructions contained in the operating instructions of
the fitting used.

Insert the electronic module 2 into the S030 sensor-fitting.

Fix with a 30° rotation.

Tighten the side screw 3 to lock the electronic module to the sensor-fitting.

Fig. 12: Installation of the SE35 onto the S030 sensor-fitting

English

Advertising
This manual is related to the following products: