Fig. 10), Fig. 11) – Burkert Type 8041 User Manual
Page 22
20
INstallation
Vertical mounting
Correct
Incorrect
flow direction
Fig. 10: Filling of the pipe
Correct
flow direction
Incorrect
Correct
Incorrect
Fig. 11: Air bubbles within the pipe
→
If necessary, use a flow conditioner to improve measurement
precision.
8.2.2. installation into the pipe of a 8041
with a G2'' nut
Observe the installation recommendations described at
chap. 8.2.1 and in the operating instructions of the S020.
→
Install the S020 fitting on the pipe.
→
Insert the nut (see mark 3, Fig. 12) on the fitting.
→
Insert the snap ring (mark 2, Fig. 12) into the groove (mark 5,
Fig. 12).
→
Position the cable glands parallel to the pipe and insert the
device (mark 1, Fig. 12) into the fitting.
→
Tighten the nut (mark 3, Fig. 12) by hand on the device.
1
2
3
5
4
Electrodes
Flow direction
Fig. 12: Installation into the pipe of the flowmeter with a G2'' nut
English
Type 8041