Fig. 33 – Burkert Type 8041 User Manual
Page 40
Advertising
38
Adjustmentandcommissioning
Calibration in progress
→
Press and hold the push
button until...
to select the calibration of the
other parameter
B
A
→
Briefly press push button.
End of calibration: red LED
goes off?
Go back to Read mode
.....
NO
to calibrate automatically
Red LED flashes:
4 times: fluid velocity < 2 m/s
5 times: fluid velocity < 10 m/s
The full scale cannot be calibrated
→
Press push button for 2 s.
Go back to Read mode using the
full scale selected or previously
calibrated.
Full scale value stored
YES
→
Wait for 10 s.
to go back to the read mode
C
Go back to Read mode without con-
firming the selection displayed.
...bargraph goes back to step
1, Fig. 32
Fig. 33: Calibration of the full scale, part 2
English
Type 8041