Figure 7-10: Eclipse Omega Matrix’s Double-Pole Double-Throw

Alarm Relay

GENERAL-PURPOSE OUTPUTS CONNECTOR

(GP OUT)

The DB-25 connector labeled “GP OUT” connects the matrix to eight
double-pole double-throw (DPDT) relays with contact ratings of 30
VDC at 1A.

Each general-purpose output has a relay inside the Eclipse Omega
matrix. When a general-purpose output is inactive, the associated
“common” pin on the GP OUT connector will be shorted to the relevant
“normally closed” pin. When a general-purpose output becomes active,
the short between the “common” pin is broken and a new connection is
made between the “common” pin and the “normally open” pin.

ALARM_COM

RL1

RELAY DPDT

3

2

4

8

9

7

1

10

ALARM_NC

ALARM_NO