INSTALLING THE ECLIPSE OMEGA MATRIX

The following overview gives a summary of the steps required to install
an Eclipse Omega matrix. More detailed information on each step is
provided in the sections that follow.

To install an Eclipse Omega matrix

1. Remove the Eclipse Omega matrix chassis from its shipping carton.
2. Leave at least 2 inches (51 mm) of clearance on all sides of the

matrix chassis to ensure proper airflow. Do not block ventilation
vents.

3. Check the position of circuit cards, power supplies, and

rear-connector panels. Later sections in this chapter give more
information on these items.

4. Apply AC power to the unit. The unit has two separate AC power

entry connectors for the two separate power supplies in the system.

INSTALLING POWER SUPPLIES

The Eclipse Omega system’s DC power supplies run on AC mains
power. Two identical Euro Cassette power supplies are provided to
ensure that every matrix will have redundant power—that is, to ensure
that the matrix will continue to operate even if one supply output fails.

Each of the power supplies must be connected to a dedicated branch
of AC mains power. The matrix will continue to operate even if one of
the AC power branches fails.

Clear-Com ships each matrix with power supplies already installed.
When the matrix is installed connect the power supplies to AC mains
power using the IEC power connectors on the matrix’s rear panel.

A fully equipped Eclipse Omega matrix (13 port cards, 2 expansion
cards) requires 100 to 240 VAC at 40 to 50 Hz with a maximum
dissipation of 300W.

INSTALLING THE REAR RJ-45 CONNECTOR
PANELS

The matrix’s rear panel is constructed of modular,
individually-installable connector panels. Each port or expansion card
has a corresponding rear-connector panel. Each MVX-A16 rear
connector panel holds 16 RJ-45 connectors. E-FIB rear cards contain
two fiber connectors and E-QUE, IVC-32 and LMC-64 rear cards
contain 11 RJ-45 connectors.

Clear-Com ships each matrix with the required number of
rear-connector panels already installed. Blank rear panels fill unused
card slots.