Installation, Reconnecting the cpu card’s backup battery, Installation -1 – Clear-Com Eclipse-Omega User Manual

Page 87: Reconnecting the cpu card’s backup battery -1

Advertising
background image

Clear-Com
Eclipse Omega Instruction Manual

7 - 1

INSTALLATION

RECONNECTING THE CPU CARD’S BACKUP
BATTERY

MPORTANT: Before the Omega is installed the CPU backup battery
must be reconnected.

The matrix CPU card has a lithium backup battery that powers the
CPU memory if the AC electricity fails. This backup battery is shipped
disconnected to preserve battery life. When the matrix is received the
battery must be reconnected.

The matrix will operate if the battery is not reconnected. However, if the
matrix is powered down all configuration information stored in the
matrix’s CPU card will be lost.

To reconnect the CPU memory’s backup battery:

1. Please observe anti-static procedures. The CPU card can be

damaged by static electricity. Anyone reconnecting the battery
should ensure that they ground themselves and all tools before
touching cards.

2. Locate CON9 on the centermost upper portion of the CPU card.

Under the CON9 heading, there are three pins. A jumper plug is
placed over pins 2 and 3. This is the OFF position.

3. Lift the jumper plug off the pins, and place it over pins 1 and 2. This

is the ON position.
The battery is now powered.

On older Eclipse Omega CPU cards the battery is normally a CR2430
3V VARTA 6430-701-501 and would be fitted on shipment. This has a
capacity of 280mAh and a life of approximately 73 days. These
batteries should only be replaced by qualified service personnel.

Later Eclipse Omega CPU cards are fitted with a socketed battery
which is normally a Renata CR2477N with a capacity of 950mAh and a
life of approximately 247 days. These socketed batteries are easily
replaced and this operation does not have to be carried out by service
personnel.

Note: If the matrix is stored for more than three months, or if the

AC power to the matrix is regularly turned off (as in Outside
Broadcast vans), a qualified service person should be
contacted to disconnect the CPU backup battery before
storing the matrix. Only a qualified service person should
attempt to disconnect the battery. To contact a qualified
service person, please see the information in the Warranty
chapter.

The Eclipse Omega matrix

installs in a standard

Electronic Industry

Association 19-inch (48 cm)

equipment rack.

7

Advertising