Each time the button is subsequently pressed the next configuration
number in the series appears in the dot-matrix display. The numbers
cycle forward until all of the choices have been displayed, then start
again at “1”.

When a non-active configuration’s number appears in the display, it
flashes to indicate its non-active status. When an active configuration’s
number (either 1,2, 3, or 4) appears in the display, it illuminates solidly
(without flashing) to indicate that it is the active configuration.

To select one of the four configurations from the CPU card

1. Repeatedly press the CONFIG button until the desired

configuration’s number (1,2,3, or 4) appears in the display.

2. When the desired number appears, press and hold the CONFIG

button until the display stops flashing. This should take about three
seconds.
The selected configuration then becomes the system’s active
operational configuration.

Engineering “ENG” Button

This button is used to reset the system to the default IP address
(169.254.0.100) with DHCP enabled and to display system information
on the LED dot matrix.

To perform an IP address reset sequence:

1. Press and hold the ‘ENG’ and ‘FULL RESET’ front panel buttons

simultaneously.

2. Press the ‘RESET’ button. If the system has two CPU cards (master

and slave) ensure that the IP address reset is performed on each
card as detailed below.

• Remove the slave CPU card if present.

• Press and hold the ‘ENG’ and ‘FULL RESET’ front panel buttons

simultaneously then press the ‘RESET’ button on the master CPU
card.

• Replace the slave CPU card if there is one otherwise the

procedure is complete.

• Remove the master CPU card.

• Press and hold the ‘ENG’ and ‘FULL RESET’ front panel buttons

simultaneously then press the ‘RESET’ button on the slave CPU
card.

• Replace the master CPU card.

System Status

If the “ENG” button only on the master CPU is pressed the following
system information will be displayed on the LED matrix:

• Eclipse release - "V5.2" at 5.2