Note: A shielded cable should be used.

RS-232 CONNECTOR

The female 9-pin D-type socket labeled “RS-232” connects the CPU
card to an external computer.

Note: A shielded cable should be used.

ALARM I/O CONNECTOR

The female 9-pin D-type socket labeled “Alarm I/O” connects the
Eclipse matrix to an external alarm indicator, such as a light or buzzer
and/or to an external alarm source.

Note: A shielded cable should be used.

GENERAL-PURPOSE OUTPUTS CONNECTOR

(“GP OUT”)

The male 25-pin D-type socket labeled “GP OUT” connects the CPU
card to eight general purpose outputs (GPOs). General-purpose
outputs are single-pole double-throw relays with contact ratings of 30
VDC (volts direct current) at 1 ampere.

A general purpose output or “relay” is a switch that is controlled
remotely. The relay is programmed in ECS to close a contact
whenever an specified intercom panel key is pressed. When the
contact is closed, it completes an electronic circuit’s signal path so that
a remote device, such as a light, is powered.

A GPO can be programmed to mute a speaker, to turn on an applause
light, to turn on a door lock, or to perform a variety of other functions.
For example, to get the attention of a panel operator working in a
high-noise environment such as a control booth, a relay can be
programmed to switch on a light at the operator panel each time an
incoming call is received, to ensure that the call is not missed.

Note: If the GP-OUT port is used on an Omega matrix fitted with

XP power supplies (part 740101Z) the following filter must
be fitted between the PROC-RCC socket and the cable:

CINCH FA-25PS/1-LF 25W D-type in-line 1000pF filter
(UK supplier: Farnell 111-4108)

If the Omega matrix is equipped with Power-One power
supplies (part 720379Z) this filter should not be fitted. If this
filter is already fitted to an Omega matrix and the power
supplies are changed to Power-One units the filter must be
removed before the matrix is powered up.

2

3

4