Clear-Com Eclipse-Omega User Manual

Page 69

Advertising
background image

Clear-Com
Eclipse Omega Instruction Manual

4 - 9

Multiple E-QUE interfaces within a single matrix do not need to have
external DECT sync cables connected as the signal uses the
backplane.

Figure 4-5: Multiple Matrices with DECT Sync Interconnect

All connections are made using CAT5 cable and it is recommended
that shielded cable is used.

Note: If an E-QUE interface is fitted in the matrix with antennae or

splitters connected and active inserting a second E-QUE
interface to the left of the first interface (seen from the front)
will cause a temporary loss of audio to beltpacks using the
original E-QUE interface (usually for about 10 seconds).
The beltpacks do not go offline and signalization is not lost.

Matrix 1

Matrix 2

E-Que
Card 1

E-Que
Card 2

Splitter 1

Splitter 2

DECT
Sync

LAN

Out

In

Advertising