CNB ID2810PVF User Manual

Page 7

Advertising
background image

XNET Network Dome Camera User’s Guide

y FL or F/L (Fickerless)

Set this switch to “ON” to prevent flicker from the following AC Power conditions:

- Using an NTSC camera in a region with 50 Hz AC power, or a PAL

camera in a region with 60 Hz AC power may cause a visible “video
flicker.”

This is outside of normal power conditions for the two aforementioned video standards.
Thus the improper 10 Hz differentiation is the cause of the “flicker.”

y D/N (Day & Night)

- Available only for Day & Night camera module

Set this switch to “ON” to enable the camera’s day & night feature set. Under very low
light conditions, the camera automatically switches to “Night Mode/Black and White Mode,”
delivering daylight quality Black & White video.

y DSS (Digital Slow Shutter)

- Available only for Day & Night camera module

Turning this switch “ON”, tells the camera to sacrifice the video refresh rate in order to
compensate for ultra low light conditions, improving the brightness and sharpness of the
video.

y ZOOM (Digital Zoom)

- Available only for Day & Night camera module

Set switch to “ON” to enable digital zoom.

y DC Level

- Available only for Day & Night camera module

For adjusting output video DC levels.

y Analog Video Output

Connect a handheld monitor to assist in adjust the viewing angle and focus right at the
camera.

A standard RCA video cable adapter is included with network camera.
To Analog Video Out of network camera To Analog Monitor






Figure 2-2. Analog Video Cable