CNB ID2810PVF User Manual

Page 9

Advertising
background image

XNET Network Dome Camera User’s Guide

y 100BaseT (RJ45)

100Mbps Ethernet connector (RJ-45) with proprietary PoE.

-

Link LED: Continuous yellow light means that network cable is plugged in. It will
flicker when there is traffic.

-

Status LED: Green color indicates that the camera is in normal operation mode,
while RED color indicates that the camera is in abnormal condition.

y DC

Power

Power input of XNET. DC 12V

<Warning>: Do not apply power through the power input jack on the back of the
camera when power is supplied through a LAN cable using proprietary PoE.
This will damage the camera!
CNBTEC assumes no responsibility for the damages
caused by applying power using both connectors.

y Sensor In/Relay Out

Used for connecting sensor, and alarm devices to XNET. Note that the each signal is
differentiated by color of cable.

Cable color

Description

Misc.

Red

Sensor In (+)

NC/NO selectable in admin mode.

Black

Sensor In (-)

NC/NO selectable in admin mode.

Orange

Relay out

Normal close

Brown Relay

out

Common

Yellow

Relay out

Normal open

„ Sensor Input : Connect external alarm sensors such as the infrared sensors, heat

sensor, magnetic sensors, etc. NC/NO selectable in the admin page.

„ Relay Output : It is used for connecting external alarm generators such as sirens,

flashing light, etc. When activated, relay output configures a closed circuit.

„ Please refer to Section 6.1 for more detailed description on the Sensor In and

Relay Out connections.