Tone timing diagrams, Transmit tone control sequence, Figure 15 transmit tone control sequence – CTI Products TSAM Transmitter Steering & Audio Matrix User Manual

Page 67: 1 transmit tone control sequence

Advertising
background image

TSAM Installation and Maintenance Rev. 2.10

Chapter 7

CTI Products, Inc.

Tone Timing Diagrams

59

7.

Tone Timing Diagrams

7.1

Transmit Tone Control Sequence

HLGT

0 dBm

FT

-10

LLGT -30 dBm + Audio

120 ms

40

(Duration of Transmission)

Standard Transmit
TRC Sequence

HLGT

0 dBm

FT

-10

LLGT -30 dBm + Audio

120 ms

40

(Duration of Transmission)

CC
-10

40

Positive Mode Control
(PMC) Transmit
TRC Sequence

FT is Function Tone (F1, F2, etc.)

HLGT & LLGT are typically 2175 Hz

CC is Coded/Clear: Coded = 1150 Hz; Clear = 1050 Hz

Timing and frequencies are programmable.