Tone timing diagrams, Transmit tone control sequence, Figure 15 transmit tone control sequence – CTI Products TSAM Transmitter Steering & Audio Matrix User Manual
Page 67: 1 transmit tone control sequence
Advertising
TSAM Installation and Maintenance Rev. 2.10
Chapter 7
CTI Products, Inc.
Tone Timing Diagrams
59
7.
Tone Timing Diagrams
7.1
Transmit Tone Control Sequence
HLGT
0 dBm
FT
-10
LLGT -30 dBm + Audio
120 ms
40
(Duration of Transmission)
Standard Transmit
TRC Sequence
HLGT
0 dBm
FT
-10
LLGT -30 dBm + Audio
120 ms
40
(Duration of Transmission)
CC
-10
40
Positive Mode Control
(PMC) Transmit
TRC Sequence
FT is Function Tone (F1, F2, etc.)
HLGT & LLGT are typically 2175 Hz
CC is Coded/Clear: Coded = 1150 Hz; Clear = 1050 Hz
Timing and frequencies are programmable.
Figure 15 Transmit tone Control Sequence