IAI America ACON-SE User Manual

Page 111

Advertising
background image

101

6. T

roubleshooting

Code Message

name

Cause/Action

20C CSTR-ON

during

operation

7KLVPHVVDJHLQGLFDWHVWKDWWKHVWDUWVLJQDO &675 EHFDPH³´E\WKH
PLC while the actuator was moving, and that duplicate movement
commands occurred as a result.

20E Soft limit over

This message indicates that a soft limit was reached.

210 HOME-ON

during

operation

This message indicates that the home return signal (HOME) became
³´E\WKH3/&ZKLOHWKHDFWXDWRUZDVPRYLQJDQGWKDWGXSOLFDWH
movement commands occurred as a result.

221 Write in monitor mode

prohibited

This message indicates that position table or parameter writing
operation was performed in the monitor mode.

223 Operation

in

monitor

mode prohibited

This message indicates that actuator movement operation was
performed in the monitor mode.

301
302
304
305
306
308

30A
30B

Overrun error (M)
Framing error (M)
SCIR-QUE OV (M)
SCIS-QUE OV (M)
R-BF OV
Response timeout (M)
Packet R-QUE OV
Packet S-QUE OV

These messages indicate an error in the serial communication with the
controller.
Cause: [1] Garbage data due to the effect of noise

[2] Duplicate slave numbers when multiple controllers are

FRQWUROOHGE\VHULDOFRPPXQLFDWLRQ

Action: [1] Adjust the wiring in a manner eliminating the effect of noise

and review the installation of equipment, etc.

[2] Change the slave numbers to avoid duplication.

,IWKHPHVVDJHLVVWLOOGLVSOD\HGDIWHUWDNLQJWKHDERYHDFWLRQVSOHDVH
contact IAI.

 0HPRU\FRPPDQG

refused

This message indicates that the command was refused in the serial
communication with the controller.

309 Write address error

This message indicates that an indeterminate WRITE address error
occurred in the serial communication with the controller.

These conditions do not occur in

QRUPDORSHUDWLRQ6KRXOGWKH\RFFXU

record the entire error list before cutting off the power for use in the
cause investigation.
Also contact IAI.

30C No connected axis

This message indicates that no controller axis number is recognized.
&DXVH>@ 7KHFRQWUROOHULVQRWRSHUDWLQJSURSHUO\

>@ 2QO\WKHVXSSOLHGFRPPXQLFDWLRQFDEOH 6*$6*% LV

disconnected.

[3] If a SIO converter is used, 24V is supplied to the converter

but the link cable is not connected.

[4] There are duplicate axis numbers when multiple controllers

are linked.

Action: [1] Check if the RDY lamp on the controller is lit. If the lamp is

QRWOLWWKHFRQWUROOHULVIDXOW\

[2] If a spare teaching pendant is available, replace the current

pendant with the spare unit, or with a PC, and see if the
message disappears.

>@ 6XSSO\SRZHUDIWHUFRQQHFWing the link cable between the

converter and controller.

[4] Make sure the axis number settings are not duplicated.

,IWKHPHVVDJHLVVWLOOGLVSOD\HGDIWHUWDNLQJWKHDERYHDFWLRQVSOHDVH
contact IAI.

Advertising