5 external connection diagram – IAI America ACON-SE User Manual

Page 36

Advertising
background image

26

3. Installation and W

iring

3.5 External

Connection

Diagram

An example of standard wiring is shown below.

(Note) When encoder relay cables are of the robot cable specification, the line colors will be different, refer

WR³(QFRGHU5HOD\&DEOHV´

ACON-SE controller

Connected to teaching
pendant/PC, gateway unit
or SIO converter

Input power
supply
24 V DC

Brake release
switch to forcibly
release the brake

External EMG

switch

Terminal block

Motor relay cable

Tighten together with the
mounting screw.

Holding brake

Encoder

Home position
check sensor

Actuator

5HG

White

Black

Encoder relay cable

Blue

Orange

Gray

5HG

Black

Yellow

Pink

Purple

Orange/White

Green/White

%OXH5HG

Green

Brown

Motor

Advertising