3 control signals, control data – IAI America ACON-SE User Manual

Page 58

Advertising
background image

48

4. Description of Operating Functions

4.3 Control Signals, Control Data

In order to operate ACON-SE via serial communication, it is required to write/read the 16-bit internal memory
(Modbus register, Modbus status) of the controller. The main signals and their symbol names handled at that time
are shown below.
For details, refer to the serial communication operation manual for your ROBO Cylinder series.

(1) Controller Input Signals

(PLC

o Controller)

Register

Bit

address

Bit

position

Signal

symbol

Signal name

Description

15





0401H 14 SFTY

Safety speed command Safety speed set with the parameter

0: Invalid, 1: Valid

13





0403H 12 SON

Servo ON command

0: Servo OFF, 1: Servo ON



±







0407H 8 RES

Alarm reset

1RUPDO³´o³´ULVHHGJH$ODUPUHVHW

7







6







Device
control
register
DRG1

Address
0D00H

040AH 5 STP

Pause command

0: Normal, 1: Pause (deceleration stop)

040BH 4 HOME

Home return command ³´ o³´ULVHHGJH+RPHUHWXUQRSHUDWLRQ

040CH 3 CSTR

Positioning start

1RUPDO³´o³´ULVHHGJH3RVLWLRQLQJVWDUW
to the target position specified with the position
no.

[Common]

*1

2

 0







*1 The meanings of [Common], [POS specification] and [Numeric specification] are as follows:
y [Common]:

Used in common in both operation by position number specification and operation by
numeric specification.

y [POS specification]:

Used in the operation by position number specification

y Numeric specification]: Used in the operation by the numeric specification