4. Description of Operating Functions

(2) Controller output signals

(Controller

o PLC)

Register

Bit

address

Bit

position

Signal

symbol

Signal name

Description

0100H 15 EMGS

Emergency stop
status

1: Under emergency stop

0101H 14 SFTY

Safety

speed

valid 1: Safety speed valid condition

0102H 13 PWR

Controller

ready

1: Controller preparation completed

0103H 12 SV Servo

ready

1: Operation preparation completed

(servo ON status)

0104H

11

PSFL Push & hold missing

1: Push & hold missing

0105H 10 ALMH

Major

failure

status

1: Alarm indicating that continuous

operation is impossible

0106H 9 ALML

Minor

failure

status

1: Alarm indicating that continuous

operation is impossible



±







010AH

5

STP

Pause commanding

1: Pause command being issued

010BH 4 HEND

Home return
completion

1: Home return completed

Device
status
register
DSS1

Address
9005H

010CH 3 PEND

Position

complete 1: Positioning completed

[Common]*



±









±







0124H 11 GHMS

Home

returning

1: Home returning

0123H

10

PUSH Push & hold operating 1: Push & hold operating



±







Expansion
device
status
register
DSSE

Address
9007H

012AH 5 MOVE

Moving

1: Moving (including home return, push &

hold operation)

>&RPPRQ@ 



±







* The meanings of [Common], [POS specification] and [Numeric specification] in the Register field are as

follows:

y [Common]:

Used in common in both operation by position number specification and
operation by numeric specification.

y [POS specification]:

Used in operation by position number specification.

y [Numeric specification]: Used in operation by numeric specification.