8 wiring the emergency stop circuit, 1 drive signal shutdown (standard), 1) when the sio converter is used – IAI America ACON-SE User Manual

Page 38: 28 3. installation and w iring, Acon-se controller

Advertising
background image

28

3. Installation and W

iring

3.8 Wiring the Emergency Stop Circuit

3.8.1

Drive Signal Shutdown (Standard)

The motor drive is stopped by the controller internal circuit.
The motor drive power supply is not shut off.

(1)

When the SIO converter is used

Caution: The input current to the EMG terminal of ACON-SE is 5 mA. When connecting the contact of

the EMG relay R to the EMG terminals of multiple controllers, check the current capacity of
the relay contact.

Teaching pendant

EMG push

button

T.P. connector

SIO converter

ACON-SE controller

EMG reset

switch

EMG

push

button

Terminal

block

Input power supply

24 VDC

SIO

communication

SIO connector

Connection
detecting
signal (H)

Drive stop

signal

(L)

Control
power
supply

Power supply terminal block

Power supply terminal block (Unit 2)

EMG signal

detection

(H)

Motor drive
power
supply

Power supply terminal block (Unit 3)

SIO

connector

connection

detecting

circuit

Ti

m

e

const

ant

Motor

drive

circuit

0V 24V