Part 2 Programs

(Note) A READ command must be executed before the other side sends the end character.

SCHA

10

OPEN

0

READ

0

2

Other side

CLOS

0

x Return code of the READ command

The return code is stored in a local variable. The variable number can be set by “Other
parameter No. 24.” The default variable number is 99.
0: READ completed successfully (Receive complete)
1: READ timeout (the timeout value is set by a TMRD command) (Continue to receive)
2: READ timer cancelled (the wait status is cancelled by a TIMC command) (Continue to

receive)

3: READ SCIF overrun error (Receive disabled)
4: READ SCIF receive error (framing error or parity error) (Receive disabled)
5: READ factor error (program abort error) (Receive disabled)

(Cannot be recognized by SEL commands)

6: READ task ended (program end request, etc.) (Receive disabled)

(Cannot be recognized by SEL commands)

7: READ SCIF receive error due to other factor (Receive disabled)
8: READ SIO overrun error (Receive disabled)
9: READ SIO parity error (Receive disabled)
10: READ SIO framing error (Receive disabled)
11: READ SIO buffer overflow error (Receive disabled)
12: READ SIO receive error due to other factor (Receive disabled)
13

a 20: Used only in Ethernet (optional)

21: READ SIO receive temporary queue overflow error (Receive disabled)
22: READ SIO slave receive queue overflow error (Receive disabled)