397

Appendix

Description

Action

Parameter

settin

g

Operation/outco

me

15

Output a signal

w

h

en all valid

axes have completed home

return.

A desired output

port can be set

as an all-valid-axes home-ret

urn

complete output.

Set the follow

ing

value in the I/O p

aramete

r “Output

function selectio

n n” corresponding to the selected input

port:

I/O pa

rameter “Output function specification va

lue” = 13

The specified port w

ill turn

ON

when all

valid axes have completed home return.

16

Output a

warning

signal w

hen

the voltage of the

sy

stem

-

memory backup

battery became

low

.

A desired output

port can be set

as a voltage-low

w

a

rning outp

ut

for the s

y

stem

-m

emory

backup

battery.

Set the follow

ing

value in the I/O p

aramete

r “Output

function selectio

n n” corresponding to the selected input

port:

I/O pa

rameter “Output function specification va

lue” = 15

The specified port w

ill turn

ON

when the

voltage of the s

y

stem-memory ba

ckup

battery became l

ow

.

17

Output a

warning

signal w

hen

the voltage of the

absolute

encoder batte

ry

became low

.

A desired output

port can be set

as a voltage-low

w

a

rning outp

ut

for the absolute

encoder batte

ry.

Set the follow

ing

value in the I/O p

aramete

r “Output

function selectio

n n” corresponding to the selected input

port:

I/O pa

rameter “Output function specification va

lue” = 16

The specified port w

ill turn

ON

when the

voltage of the ab

solute encoder b

a

ttery

became low

.

18

Release the brak

e using an

external input signal.

A desired input p

o

rt can be set as

a forced brake

-re

lease input.

Set the follow

ing

value in each I/O paramete

r “Inp

ut

function selectio

n n” corresponding to the selected input

port:

I/O pa

rameter “In

put function specification value” =

22

(Axis 1)

I/O pa

rameter “In

put function specification value” =

23

(Axis 2)

Setting example) To set input port

No. 12 as the b

rake

release input for

axis 2, set “23” in

I/O pa

ramete

r N

o.

42.

The brake

w

ill be forcibly

released w

h

en

the specified port turns ON

.

19

Retain output co

nditions upon

actuation of an e

m

ergenc

y

stop

or opening of t

he

safet

y

gate.

The minimum an

d maximum

output port

numb

ers can be set to

specify

a

range o

f outputs

w

hose

condition is to be retained.

I/O pa

rameter N

o. 70 = Min. outp

ut port num

ber

I/O pa

rameter N

o. 71 = Max.

out

put port nu

mber

Setting example) To retain th

e conditions of output

port

Nos. 303 thro

ugh

307, set as follow

s:

I/O pa

rameter N

o. 70 = 303

I/O pa

rameter N

o. 71 = 307

m

The con

ditions of output port

N

o

s.

303 throu

gh 307

w

ill be retained

w

hen

the emerge

nc

y

st

op input turns

ON or

the safet

y

gat

e o

pens.

20

Start a program

w

h

en the

emergenc

y stop input turns

ON

or the safet

y gat

e opens.

Programs that ca

n be started in

these conditions are limited to

those not contain

ing I/O

processing, calculation

processing or an

y othe

r

processing involving actuator

operation (PI

O p

rocessing

programs

).

A PIO processing program to be

started in these conditions can be

set. The pro

gram

number of t

he

applicable PIO processing

program

, and the

minimum and

maximum outpu

t

port numbe

rs

indicating the range of processed

outputs, are set

b

y

pa

ramete

rs.

Other

param

eter

No. 2 = PIO p

roc

essing program

number

Other

param

eter

No. 70 = Min. out

put port nu

mber

Other

param

eter

No. 71 = Ma

x. ou

tput port n

umber

Setting example) To start p

rogram

No. 5 that p

roce

sses

output port

Nos.

303 throu

gh 307,

set as follow

s:

Other

param

eter

No. 2 = 5

Other

param

eter

No. 70 = 303

Other

param

eter

No. 71 = 307

m

Program No.

5 w

ill start

w

hen the

emergenc

y stop input turns

ON o

r

the

safet

y

gate o

pen

s.

Output p

ort N

os. 303 throu

gh 307

can

be processed.

Advertising