I/o parameters, 1 i/o parameters – IAI America SSEL User Manual

Page 424

Advertising
background image

402

Appendix

1. I/O

Parameters

1.1 I/O

Parameters

No. Parameter

name

Default

value

(Reference)

Input range

Unit

Remarks

1

I/O port assignment type

1

0 ~ 20

0: Fixed assignment

2

Input port start number
with fixed standard I/O
assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

3

Output port start number
with fixed standard I/O
assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

4 ~ 9 For future expansion

-1

-1 ~ 599

10

Standard I/O error
monitor

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O

power source)

3: Monitor (Monitor only errors relating to 24-V I/O power

source)

* Some exceptions apply.
* If this parameter is set to “0” (= Do not monitor) or “2” (=

Do not monitor errors relating to 24-V I/O power
source), a system error will not generate even when the
24-V I/O power source presents abnormality. However,
the actual outputs from digital I/Os will be cut off by
circuitry thereafter to protect the controller.

11 ~

13

For future expansion

1

0 ~ 5

14 Network

system

reservation

0

0 ~ 256

15 Network

system

reservation

0

0 ~ 256

16 Network

system

reservation

-1

-1 ~ 599

17 Network

system

reservation

-1

-1 ~ 599

18 Network

system

reservation

1

0 ~ 5

19 (For

expansion)

0

20

Input filtering periods

2

1 ~ 9

msec Input signal is recognized when the status is held for twice

the period set by this parameter.

21

For future expansion
(change prohibited)

0

1 ~ 9

22

For future expansion

0

0 ~ 99999

msec

23

For future expansion

0H

0H ~

FFFFFFFFH

24

I/O setting bit pattern 1

10000H

0H ~

FFFFFFFFH

Bits 0 to 3: RDY OUT function selection (System IO)

(0: SYSRDY (Software = PIO trigger program

can be run) and hardware is normal
(emergency stop has not been actuated
and hardware error is not present)

1: Error of operation-cancellation level or

higher is not present

2: Error of cold-start level or higher is not

present)

Bits 4 to 7: RDY LED function selection

(0: Program can be run

1: Error of operation-cancellation level or

higher is not present

2: Error of cold-start level or higher is not

present)

Bits 8 to 19: For future expansion

25

I/O setting bit pattern 2

0H

0H ~

FFFFFFFFH

26 (For

expansion)

0

27 (For

expansion)

0

28 (For

expansion)

0