Wiring accessories to the control board, Additional features – LiftMaster LA500 Residential / Light Commercial Swing Gate Operator User Manual

Page 35

Advertising
background image

33

ADDITIONAL FEATURES

A Single Button Control,

SBC (2 terminals)

Gate command sequence - Open, Stop, Close, Stop, ...

Soft open (maintained switch does not override

external safeties and does not reset alarm condition)

B Fire Dept Open Input

(2 terminals)

Acts as hard open.

Maintained input overrides (ignores) external safeties

(photoelectric sensor and edge), pauses Timer-to-Close

momentary input logic as single button control and

safeties remain active, re-enables Timer-to-Close.

C Exit Loop Input

(2 terminals)

Open command - opens a closed gate.

Soft open (maintained switch does not override

external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

D Shadow Loop Input

(2 terminals)

Loop detector connection when loop is positioned

under gate.

- Holds open gate at open limit

- Disregarded during gate motion

- Pauses Timer-to-Close at OPEN limit

E

CLOSE EYES/Interrupt

Loop Input

(2 terminals)

CLOSE EYES/Interrupt Loop detector connection when

loop is along the side of the gate.

- Holds open gate at open limit

- Stops and reverses a closing gate to open limit

- Pauses Timer-to-Close at OPEN limit
Close Direction Photoelectric Sensors, IR, or Infra-red

detector wired to CLOSE EYES Input, disregarded

during gate opening.

Pulsed Photoelectric Sensors = monitored device

putting out a pulse train when unblocked.

Photoelectric Sensors, IR, Infra-red detector, normally

open contact, contact opens fully with obstruction.

F

Close Edge

(2 terminals)

Close Direction Edge Sensor to Close Safety Input,

disregarded during gate opening

G Open Eyes/Edge

(2 terminals)

Open Direction Photoelectric Sensors, IR, Infra-red

detector wired or Edge Sensor to Close Entrapments

Input, disregarded during gate closing,
Pulsed Photoelectric Sensors = monitored device

putting out a pulse train when unblocked.
Photoelectric Sensors, IR, Infra-red detector, edge

sensor = normally open contact, contact reverses for

2 seconds with obstruction.

H Lock Outputs:

Maglock

(2 terminals, N.C. and

COM)

Relay contact output, Normally - closed (N.C.) output

for maglocks
Relay activates prior to motor activation and during

motor run. Relay is off when motor is off.

I

Solenoid Lock &

Common

(2 terminals, N.O.

and COM)

Normally - open (N.O.) output for solenoid locks

Relay activates prior to motor activation and during

motor run. Relay is off when motor is off.

J

Accessory Power Out

Switched, (2

terminals)

Switched ON with gate motion (stays on 5 seconds

after motion)

K Accessory Power Out

Un-switched, (2

terminals)

24 Vdc voltage out to power accessories, always ON

WIRING ACCESSORIES TO THE CONTROL BOARD

WIRING ACCESSORIES TO THE CONTROL BOARD

Refer to the chart below and the corresponding image for a description of the control

board inputs.

X

OPEN

CLOSE

ST
OP

DIAGNOSTIC

CODES

SBC

“FIRE

DEPT.”

OPEN

EXIT

SHADOW

CLOSE

EYES/

INTERRUPT

LOCK

N.O

.

COM

N.C

.

+ -

+ -

A

CCESSOR

Y

PO

WER

ON SW

.

EXP

.

BO

ARD

K

CLASS 2 SUPPLY

24 VOLTS

- +

+ -

ID RESET

ALARM

GROUND

SBC

Com

Com

Com

Com

Com

Fire Dept

Exit

Shadow

Interrupt

Close (+)

Close (-)

Lock N.C. (Maglock)
Com

Lock N.O. (Solenoid)
Com (-)
AccPower +24 Vdc
Com (-)

AccPower +24 Vdc

Single Button

Control Station

Fire Dept.

Exit Loop

Shadow Loop

Interrupt Loop

Open Direction

Safety
Close Direction

Safety

Mag and Solenoid

Lock

A

B
C
D

E

F
G

H

I
J
K

Acc. Power

Open (+)

Open (-)

(right side of control board)