Ul325 model classifications, Safety – LiftMaster LA500 Residential / Light Commercial Swing Gate Operator User Manual

Page 4

Advertising
background image

2

In order to complete a proper installation you must satisfy the entrapment

protection chart shown. That means that the installation must have one primary

means of entrapment protection and one independent secondary means of

entrapment protection. Both primary and secondary entrapment protection

methods must be designed, arranged or configured to protect against

entrapments in both the open and close directions of gate travel.
For Example: For a gate system that is installed on a single-family residence

(UL325 Class I) you must provide the following: As your primary type of

entrapment protection you must provide
• Type A - Inherent (built into the operator) entrapment sensing and at

least one of the following as your secondary entrapment

protection:

• Type B1 - Non-contact sensors such as photoelectric sensors,

• Type B2 - Contact sensors such as gate edges

CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR

A vehicular gate operator (or system) intended for use in a home of one-to four

single family dwellings, or a garage or parking area associated therewith.

CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR

GATE OPERATOR

A vehicular gate operator (or system) intended for use in a commercial location or

building such as a multi-family housing unit (five or more single family units) hotel,

garage, retail store or other building servicing the general public.

CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR

GATE OPERATOR

A vehicular gate operator (or system) intended for use in a industrial location or

building such as a factory or loading dock area or other location not intended to

service the general public.

CLASS IV– RESTRICTED ACCESS VEHICULAR GATE

OPERATOR

A vehicular gate operator (or system) intended for use in a guarded industrial

location or building such as an airport security area or other restricted access

locations not servicing the general public, in which unauthorized access is prevented

via supervision by security personnel.

UL325 ENTRAPMENT PROTECTION REQUIREMENTS

This chart illustrates the entrapment protection requirements for the UL325 classes.

NOTE: UL requires that all installations must have warning signs placed in plain

view on both sides of the gate to warn pedestrians of the dangers of motorized gate

systems.

I

II

III

IV

UL325 MODEL CLASSIFICATIONS

SAFETY

UL325 MODEL CLASSIFICATIONS

GATE OPERATOR ENTRAPMENT PROTECTION

UL325 Classification

Swing Gate Operator

Primary Type

Secondary Type

CLASS I-CLASS IV

A

B1 or B2

Advertising