Wiring accessories to the expansion board, Additional features – LiftMaster LA500 Residential / Light Commercial Swing Gate Operator User Manual

Page 37

Advertising
background image

35

Com

Single Button Control Station

A

SBC

3-Button Control Station

B

C

Com

Open

Close

Stop

AUX Relay 2 N.C.

Com

AUX Relay 2 N.O.

AUX Relay 1 N.C.

Com

AUX Relay 1 N.O.

Exit Loop

Interrupt Loop

Shadow Loop

D

E

F

G

H

I

ADDITIONAL FEATURES

A

Open Input (& common)

(3-Button Control Station, 4 terminals total)

Open command - opens a closed gate.

Soft open (maintained switch does not override external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

B

Close Input (& common)

(3-Button Control Station, 4 terminals total)

Close command - closes an open gate.

Soft close (maintained switch does not override external safeties and does not reset alarm condition)

C

Stop Input (& common)

(3-PB station, 4 terminals total)

Stop command - stops a moving gate.

Hard stop (maintained switch overrides Open and Close commands and resets alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Overrides an Open or Close command.

D

Single Button Control, SBC (2 terminals)

Gate command sequence - Open, Stop, Close, Stop, ...

Soft Open ,Soft Close, Soft Stop (maintained switch does not override external safeties and does not reset alarm condition)

E

Exit Loop Input (2 terminals)

Loop wire connection for plug-in loop detector when loop is inside secured area near gate.

Open command - opens a closed gate.

Soft open (maintained switch does not override external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

F

Shadow Loop Input (2 terminals)

Loop wire connection for plug-in loop detector when loop is positioned under the gate.

- Holds open gate at open limit

- Disregarded during gate motion

- Pauses Timer-to-Close at Open Limit

G

Interrupt Loop Input (2 terminals)

Loop wire connection for plug-in loop detector when loop is along the side of the gate.

- Holds open gate at open limit

- Stops and reverses a closing gate

- Pauses Timer-to-Close at Open Limit

H

AUX Relay #1

Normally - open and normally - closed relay contacts to control external devices,

Function of relay contact activation determined by AUX Relay #1 option switch settings. (For connection of Class 2, low voltage

(42 Vdc [34 Vac] max 5 Amps, power sources only)

I

AUX Relay #2

Normally-open and normally-closed relay contacts to control external devices,

Function of relay contact activation determined by AUX Relay #2 option switch settings. (For connection of Class 2, low voltage

(42 Vdc [34 Vac] max 5 Amps, power sources only)

Aux Relay

N.C.
COM
N.O.

Class 2 Power Source

(42 Vdc [34 Vac],

5 A max)

+

Warning Light

AUX RELAY WIRING EXAMPLE

WIRING ACCESSORIES TO THE EXPANSION BOARD

WIRING ACCESSORIES TO THE EXPANSION BOARD

Refer to the chart below and the corresponding image for a description of the expansion board inputs.

Advertising