43

TROUBLESHOOTING CHART

TROUBLESHOOTING

FAULT

POSSIBLE CAUSES

CORRECTIONS

Gate opens, but will

not close.

a) Check DIAGNOSTIC LEDs
b) Open control active
c) Close Entrapment Protection Device active
d) Vehicle loop detector active
e) Loss of AC power with AC FAIL set to OPEN
f) Low battery with LOW BATT set to OPEN
g) Fire Dept input active

a) Use Diagnostic code to identify issue
b) Check all Open inputs for an active input
c) Check all Entrapment Protection Device inputs for an active sensor
d) Check all vehicle detector inputs for an active detector
e) Check AC power and AC Fail option setting
f)

Battery voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or

replace batteries

g) Check Fire Dept input

Gate closes, but will

not open.

a) Check DIAGNOSTIC LEDs
b) Open Entrapment Protection Device active
c) Vehicle loop detector active
d) Low battery with LOW BATT switch set to close
e)

Low battery with LOW BATT option set to

CLOSE

a) Use Diagnostic code to identify issue
b) Check all Entrapment Protection Device inputs for an active sensor
c) Check all vehicle detector inputs for an active detector
d) Battery voltage must be 22.0 Vdc or higher
e)

Check if AC power is available. If no AC power, then running on batteries and battery

voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace

batteries

Gate does not close

from Timer-to-Close.

a) Timer-to-Close not set
b) Open control active
c) Close Entrapment Protection Device active
d) Vehicle loop detector active
e) Loss of AC power with AC FAIL set to OPEN
f) Low battery with LOW BATT option set to OPEN
g) Fire Dept input active

a) Check Timer-to-Close (TTC) setting
b) Check all Open inputs for an active input
c) Check all Entrapment Protection Device inputs for an active sensor
d) Check all vehicle detector inputs for an active detector
e) Check AC power and AC Fail option setting
f)

Check if AC power is available. If no AC power, then running on batteries and battery

voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace

batteries.

g) Check Fire Dept input

Vehicle Exit loop

activation does not

cause gate to open.

a) Check DIAGNOSTIC LEDs
b) Exit vehicle detector setup incorrectly
c) Defective Exit loop detector or loop wire
d)

Low battery with LOW BATT option set to

CLOSE

a) Use Diagnostic code to identify issue
b) Review Exit loop detector settings. Adjust settings as needed.
c) Check Exit loop wire. Replace defective Exit loop detector.
d)

Check if AC power is available. If no AC power, then running on batteries and battery

voltage must be 22.0 Vdc or higher. Charge batteries by AC or solar power or replace

batteries.

Vehicle Interrupt

loop does not cause

gate to stop and

reverse.

a) Check DIAGNOSTIC LEDs
b) Vehicle detector setup incorrectly
c) Defective vehicle loop detector or loop wire

a) Use Diagnostic code to identify issue
b) Review Interrupt loop detector settings. Adjust settings as needed
c) Check Interrupt loop wire. Replace defective Interrupt loop detector

Vehicle Shadow loop

does not keep gate

at open limit.

a) Check DIAGNOSTIC LEDs
b) Vehicle detector setup incorrectly
c) Defective vehicle loop detector or loop wire

a) Use Diagnostic code to identify issue
b) Review Shadow loop detector settings. Adjust settings as needed
c) Check Shadow loop wire. Replace defective Shadow loop detector

Obstruction in gates

path does not cause

gate to stop and

reverse

a) Force setting too high

a)

Adjust force setting. Retest that obstruction in gate’s path causes gate to stop and reverse

direction.

Photoelectric sensor

does not stop or

reverse gate.

a) Incorrect photoelectric sensor wiring
b) Defective photoelectric sensor

a)

Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes

moving gate to stop, and may reverse direction.

b)

Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes

moving gate to stop, and may reverse direction.

Edge Sensor does

not stop or reverse

gate.

a) Incorrect edge sensor wiring
b) Defective edge sensor

a)

Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop

and reverse direction.

b)

Replace defective edge sensor. Retest that activating edge sensor causes moving gate to

stop and reverse direction.