Operator's Manual

Save/Recall Waveforms

Waveforms files created outside the WaveStation can be saved to and recalled from a memory bank on the
WaveStation.

1. Insert the drive into the USB host port on the front of the WaveStation.

2. Press the Utility function button, then press the Store/Recall softkey.

3. Press the FileType softkey until Data is selected.

4. Press the Browser softkey until Directory is selected, then turn the Adjust knob until USB Device is

selected.

5. Press the Browser softkey to select File. The cursor switches to the file list at the right side of the display.

6. Turn the Adjust knob to select the desired memory bank, ARB(16k) or ARB(512k), then press Select.The dis-

play changes to show a table of waveform files.

7. Turn the Adjust knob until the desired cell/file is selected.

NOTE: If possible, choose an empty cell when saving a file. Any prior data saved in that location will be
overwritten.

8. Press Save to store the file, or Recall to output it using WaveStation.

NOTE: 512K files must be output via Channel 2.

9. When saving data files, use the

keyboard

to change the File Name.

Delete Setup or Waveform File

Follow the Save/Recall procedures to navigate to the setup or data file. With the file selected from the File List
at the right side of the Browser, press the Delete softkey.

Copy Channel Settings

The setups from either WaveStation channel can be quickly copied to the other. Complete your waveform
configuration on the source channel, then:

1. Press the Utility function button.

2. Press the Channel Copy softkey.

3. Press either CH1=>CH2 or CH2=>CH1, depending on the direction you wish to copy.

4. Press Done.