Troubleshooting your E6474A system

Device communication problems

Occasionally, when you probe a COM port, the error message
in

Figure 102

may be displayed

Figure 102 No device error message

Causes

This message is displayed for the following reasons:

A device connected to a serial port or USB port is not

powered on.

The device has a defective interface cable.

The serial port has no device connected to it.

A phone is communicating at the wrong baud rate.

The device itself is defective.

Remedies

Before using the Probe Device command to probe the

COM port to identify the devices, verify that all devices
are connected and powered on. Devices include phones,
receivers, and navigators. Refer to Chapter 3 for cable
connection details.

If you have an iDEN phone, perform the procedure under

“Setting an iDEN phone’s baud rate"

on page 125.

Use a systematic approach to isolate a hardware problem.

If available, replace a suspected defective device or cable
with a known working device or cable. Replace only one
component at a time, then retest.